SSD, flash, Non-volatile memory (NVM) storage Trends, Tips & Topics

SSD, flash, Non-volatile memory (NVM) storage Trends, Tips & Topics

Updated 2/2/2018

server storage I/O trends

Will 2017 be there year of solid state device (SSD), all flash, or all Non-volatile memory (NVM) based storage data centers and data infrastructures?

Recently I did a piece over at InfoStor looking at SSD trends, tips and related topics. SSDs of some type, shape and form are in your future, if they are not already. In my InfoStor piece, I look at some non-volatile memory (NVM) and SSD trends, technologies, tools and tips that you can leverage today to help prepare for tomorrow. This also includes NVM Express (NVMe) based components and solutions.

By way of background, SSD can refer to solid state drive or solid state device (e.g. more generic). The latter is what I am using in this post. NVM refers to different types of persistent memories, including NAND flash and its variants most commonly used today in SSDs. Other NVM mediums include NVRAM along with storage class memories (SCMs) such as 3D XPoint and phase change memory (PCM) among others. Let’s focus on NAND flash as that is what is primarily available and shipping for production enterprise environments today.

Continue reading about SSD, flash, NVM and related trends, topics and tips over at InfoStor by clicking here.

Where To Learn More

Additional related content can be found at:

What This All Means

Will 2017 finally be the year of all flash, all SSD and all NVM including emerging storage class memories (SCM)? Or as we have seen over the past decade increasing adoption as well as deployment in most environments, some of which have gone all SSD or NVM. In the meantime it is safe to say that NVMe, NVM, SSD, flash and other related technologies are in your future in some shape or form as well as quantity. Check out my piece over at InfoStor SSD trends, tips and related topics.

What say you, are you going all flash, SSD or NVM in 2017, if not, what are your concerns or constraints and plans?

Ok, nuff said, for now…

Cheers
Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, vSAN and VMware vExpert. Author Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press) and <a “https://storageioblog.com/book1”>Resilient Storage Networks (Elsevier) and twitter @storageio. Watch for the spring 2017 release of his new book “Software-Defined Data Infrastructure Essentials” (CRC Press).

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2023 Server StorageIO(R) and UnlimitedIO All Rights Reserved

Server storage I/O performance benchmark workload scripts Part I

Server storage I/O performance benchmark workload scripts Part I

Server storage I/O performance benchmark workload scripts

Update 1/28/2018

This is part one of a two-part series of posts about Server storage I/O performance benchmark workload tools and scripts. View part II here which includes the workload scripts and where to view sample results.

There are various tools and workloads for server I/O benchmark testing, validation and exercising different storage devices (or systems and appliances) such as Non-Volatile Memory (NVM) flash Solid State Devices (SSDs) or Hard Disk Drives (HDD) among others.

NVMe ssd storage
Various NVM flash SSD including NVMe devices

For example, lets say you have an SSD such as an Intel 750 (here, here, and here) or some other vendors NVMe PCIe Add in Card (AiC) installed into a Microsoft Windows server and would like to see how it compares with expected results. The following scripts allow you to validate your system with those of others running the same workload, granted of course your mileage (performance) may vary.

server storage I/O SCM NVM SSD performance

Why Your Performance May Vary

Reasons you performance may vary include among others:

  • GHz Speed of your server, number of sockets, cores
  • Amount of main DRAM memory
  • Number, type and speed of PCIe slots
  • Speed of storage device and any adapters
  • Device drivers and firmware of storage devices and adapters
  • Server power mode setting (e.g. low or balanced power vs. high-performance)
  • Other workload running on system and device under test
  • Solar flares (kp-index) among other urban (or real) myths and issues
  • Typos or misconfiguration of workload test scripts
  • Test server, storage, I/O device, software and workload configuration
  • Versions of test software tools among others

Windows Power (and performance) Settings

Some things are assumed or taken for granted that everybody knows and does, however sometimes the obvious needs to be stated or re-stated. An example is remembering to check your server power management settings to see if they are in energy efficiency power savings mode, or, in high-performance mode. Note that if your focus is on getting the best possible performance for effective productivity, then you want to be in high performance mode. On the other hand if performance is not your main concern, instead a focus on energy avoidance, then low power mode, or perhaps balanced.

For Microsoft Windows Servers, Desktop Workstations, Laptops and Tablets you can adjust power settings via control panel and GUI as well as command line or Powershell. From command line (privileged or administrator) the following are used for setting balanced or high-performance power settings.

Balanced

powercfg.exe /setactive 381b4222-f694-41f0-9685-ff5bb260df2e

High Performance

powercfg.exe /setactive 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c

From Powershell the following set balanced or high-performance.

Balanced
PowerCfg -SetActive "381b4222-f694-41f0-9685-ff5bb260df2e"

High Performance
PowerCfg -SetActive "8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c"

Note that you can list Windows power management settings using powercfg -LIST and powercfg -QUERY

server storage I/O power management

Btw, if you have not already done so, enable Windows disk (HDD and SSD) performance counters so that they appear via Task Manager by entering from a command prompt:

diskperf -y

Workload (Benchmark) Simulation Test Tools Used

There are many tools (see storageio.com/performance) that can be used for creating and running workloads just as there are various application server I/O characteristics. Different server I/O and application performance attributes include among others read vs. write, random vs. sequential, large vs. small, long vs. short stride, burst vs. sustain, cache and non-cache friendly, activity vs. data movement vs. latency vs. CPU usage among others. Likewise the number of workers, jobs, threads, outstanding and overlapped I/O among other configuration settings can have an impact on workload and results.

The four free tools that I’m using with this set of scripts are:

  • Microsoft Diskspd (free), get the tool and bits here or here (open source), learn more about Diskspd here.
  • FIO.exe (free), get the tool and bits here or here among other venues.
  • Vdbench (free with registration), get the tool and bits here or here among other venues.
  • Iometer (free), get the tool and bits here among other venues.

Notice: While best effort has been made to verify the above links, they may change over time and you are responsible for verifying the safety of links and your downloads.

Where To Learn More

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

Remember, everything is not the same in the data center or with data infrastructures that support different applications.

While some tools are more robust or better than others for different things, ultimately it’s usually not the tool that results in a bad benchmark or comparison, it’s the configuration or lack of including workload settings that are not relevant or applicable. The best benchmark, workload or simulation is your own application. Second best is one that closely resembles your application workload characteristics. A bad benchmark is one that has no relevance to your environment, application use scenario. Take and treat all benchmark or workload simulation results with a grain of salt as something to compare, contrast or make reference to in the proper context. Read part two of this post series to view test tool workload scripts along with sample results.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

Part II – Some server storage I/O workload scripts and results

Part II – Some server storage I/O workload scripts and results

server storage I/O trends

Updated 1/28/2018

This is the second in a two part series of posts pertaining to using some common server storage I/O workload benchmark tools and scripts. View part I here which includes overview, background and information about the tools used and related topics.

NVMe ssd storage
Various NVM flash SSD including NVMe devices

Following are some server I/O benchmark workload scripts to exercise various storage devices such as Non-Volatile Memory (NVM) flash Solid State Devices (SSDs) or Hard Disk Drives (HDD) among others.

The Workloads

Some ways that can impact the workload performance results besides changing the I/O size, read write, random sequential mix is the number of threads, workers and jobs. Note that in the workload steps, the larger 1MB and sequential scenarios have fewer threads, workers vs. the smaller IOP or activity focused workloads. Too many threads or workers can cause overhead and you will reach a point of diminishing return at some point. Likewise too few and you will not drive the system under test (SUT) or device under test (DUT) to its full potential. If you are not sure how many threads or workers to use, run some short calibration tests to see the results before doing a large, longer test.

Keep in mind that the best benchmark or workload is your own application running with similar load to what you would see in real world, along with applicable features, configuration and functionality enabled. The second best would be those that closely resemble your workload characteristics and that are relevant.

The following workloads involved a system test initiator (STI) server driving workload using the different tools as well as scripts shown. The STI sends the workload to a SUT or DUT that can be a single drive, card or multiple devices, storage system or appliance. Warning: The following workload tests does both reads and writes which can be destructive to your device under test. Exercise caution on the device and file name specified to avoid causing a problem that might result in you testing your backup / recovery process. Likewise no warranty is given, implied or made for these scripts or their use or results, they are simply supplied as is for your reference.

The four free tools that I’m using with this set of scripts are:

  • Microsoft Diskspd (free), get the tool and bits here or here (open source), learn more about Diskspd here.
  • FIO.exe (free), get the tool and bits here or here among other venues.
  • Vdbench (free with registration), get the tool and bits here or here among other venues.
  • Iometer (free), get the tool and bits here among other venues.

Notice: While best effort has been made to verify the above links, they may change over time and you are responsible for verifying the safety of links and your downloads

Microsoft Diskspd workloads

Note that a 300GB size file named iobw.tst on device N: is being used for performing read and write I/Os to. There are 160 threads, I/O size of 4KB and 8KB varying from 100% Read (0% write), 70% Read (30% write) and 0% Read (100% write) with random (seek) and no hardware or software cache. Also specified are to collect latency statistics, a 30 second warm up ramp up time, and a quick 5 minute duration (test time). 5 minutes is a quick test for calibration, verify your environment however relatively short for a real test which should be in the hours or more depending on your needs.

Note that the output results are put into a file with a name describing the test tool, workload and other useful information such as date and time. You may also want to specify a different directory where output files are placed.

diskspd.exe -c300G -o160 -t160 -b4K -w0 -W30 -d300 -h -fr  N:iobw.tst -L  > DiskSPD_300G_4KRan100Read_160x160_072416_8AM.txt
diskspd.exe -c300G -o160 -t160 -b4K -w30 -W30 -d300 -h -fr  N:iobw.tst -L  > DiskSPD_300G_4KRan70Read_160x160_072416_8AM.txt
diskspd.exe -c300G -o160 -t160 -b4K -w100 -W30 -d300 -h -fr  N:iobw.tst -L  > DiskSPD_300G_4KRan0Read_160x160_072416_8AM.txt
diskspd.exe -c300G -o160 -t160 -b8K -w0 -W30 -d300 -h -fr  N:iobw.tst -L  > DiskSPD_300G_8KRan100Read_160x160_072416_8AM.txt
diskspd.exe -c300G -o160 -t160 -b8K -w30 -W30 -d300 -h -fr  N:iobw.tst -L  > DiskSPD_300G_8KRan70Read_160x160_072416_8AM.txt
diskspd.exe -c300G -o160 -t160 -b8K -w100 -W30 -d300 -h -fr  N:iobw.tst -L  > DiskSPD_300G_8KRan0Read_160x160_072416_8AM.txt

The following Diskspd tests use similar settings as above, however instead of random, sequential is specified, threads and outstanding I/Os are reduced while I/O size is set to 1MB, then 8KB, with 100% read and 100% write scenarios. The -t specifies the number of threads and -o number of outstanding I/Os per thread.

diskspd.exe -c300G -o32 -t132 -b1M -w0 -W30 -d300 -h -si  N:iobw.tst -L  > DiskSPD_300G_1MSeq100Read_32x32_072416_8AM.txt
diskspd.exe -c300G -o32 -t132 -b1M -w100 -W30 -d300 -h -si  N:iobw.tst -L  > DiskSPD_300G_1MSeq0Read_32x32_072416_8AM.txt
diskspd.exe -c300G -o160 -t160 -b8K -w0 -W30 -d300 -h -si  N:iobw.tst -L  > DiskSPD_300G_8KSeq100Read_32x32_072416_8AM.txt
diskspd.exe -c300G -o160 -t160 -b8K -w100 -W30 -d300 -h -si  N:iobw.tst -L  > DiskSPD_300G_8KSeq0Read_32x32_072416_8AM.txt

Fio.exe workloads

Next are the fio workloads similar to those run using Diskspd except the sequential scenarios are skipped.

fio --filename=N\:\iobw.tst --filesize=300000M --direct=1  --rw=randrw --refill_buffers --norandommap --randrepeat=0 --ioengine=windowsaio  --ba=4k --bs=4k --rwmixread=100 --iodepth=32 --numjobs=5 --exitall --time_based  --ramp_time=30 --runtime=300 --group_reporting --name=xxx  --output=FIO_300000M_4KRan100Read_5x32_072416_8AM.txt
fio --filename=N\:\iobw.tst --filesize=300000M --direct=1  --rw=randrw --refill_buffers --norandommap --randrepeat=0 --ioengine=windowsaio  --ba=4k --bs=4k --rwmixread=70 --iodepth=32 --numjobs=5 --exitall --time_based  --ramp_time=30 --runtime=300 --group_reporting --name=xxx  --output=FIO_300000M_4KRan70Read_5x32_072416_8AM.txt
fio --filename=N\:\iobw.tst --filesize=300000M --direct=1  --rw=randrw --refill_buffers --norandommap --randrepeat=0 --ioengine=windowsaio  --ba=4k --bs=4k --rwmixread=0 --iodepth=32 --numjobs=5 --exitall --time_based  --ramp_time=30 --runtime=300 --group_reporting --name=xxx  --output=FIO_300000M_4KRan0Read_5x32_072416_8AM.txt
fio --filename=N\:\iobw.tst --filesize=300000M --direct=1  --rw=randrw --refill_buffers --norandommap --randrepeat=0 --ioengine=windowsaio  --ba=8k --bs=8k --rwmixread=100 --iodepth=32 --numjobs=5 --exitall --time_based  --ramp_time=30 --runtime=300 --group_reporting --name=xxx  --output=FIO_300000M_8KRan100Read_5x32_072416_8AM.txt
fio --filename=N\:\iobw.tst --filesize=300000M --direct=1  --rw=randrw --refill_buffers --norandommap --randrepeat=0 --ioengine=windowsaio  --ba=8k --bs=8k --rwmixread=70 --iodepth=32 --numjobs=5 --exitall --time_based  --ramp_time=30 --runtime=300 --group_reporting --name=xxx  --output=FIO_300000M_8KRan70Read_5x32_072416_8AM.txt
fio --filename=N\:\iobw.tst --filesize=300000M --direct=1  --rw=randrw --refill_buffers --norandommap --randrepeat=0 --ioengine=windowsaio  --ba=8k --bs=8k --rwmixread=0 --iodepth=32 --numjobs=5 --exitall --time_based  --ramp_time=30 --runtime=300 --group_reporting --name=xxx  --output=FIO_300000M_8KRan0Read_5x32_072416_8AM.txt

Vdbench workloads

Next are the Vdbench workloads similar to those used with the Microsoft Diskspd scenarios. In addition to making sure Vdbench is installed and working, you will need to create a text file called seqrxx.txt containing the following:

hd=localhost,jvms=!jvmn
sd=sd1,lun=!drivename,openflags=directio,size=!dsize
wd=mix,sd=sd1
rd=!jobname,wd=mix,elapsed=!etime,interval=!itime,iorate=max,forthreads=(!tthreads),forxfersize=(!worktbd),forseekpct=(!workseek),forrdpct=(!workread),openflags=directio

The following are the commands that call the Vdbench script file. Note Vdbench puts output files (yes, plural there are many results) in a output folder.

vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=4k workseek=100 workread=100 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o  vdbench_NNVMe_300GB_64JVM_160TH_4K100Ran100Read_0726166AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=4k workseek=100 workread=70 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_4K100Ran70Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=4k workseek=100 workread=0 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_4K100Ran0Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=8k workseek=100 workread=100 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_8K100Ran100Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=8k workseek=100 workread=70 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_8K100Ran70Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=8k workseek=100 workread=0 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_8K100Seq0Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=8k workseek=0 workread=100 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_8K100Seq100Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=8k workseek=0 workread=70 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_8K100Seq70Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=160 jvmn=64 worktbd=8k workseek=0 workread=0 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_160TH_8K100Seq0Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=32 jvmn=64 worktbd=1M workseek=0 workread=100 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_32TH_1M100Seq100Read_072416_8AM
vdbench -f seqrxx.txt dsize=300G  tthreads=32 jvmn=64 worktbd=1M workseek=0 workread=0 jobname=NVME etime=300 itime=30 drivename="\\.\N:\iobw.tst" -o vdbench_NNVMe_300GB_64JVM_32TH_1M100Seq0Read_072416_8AM

Iometer workloads

Last however not least, lets do an Iometer run. The following command calls an Iometer input file (icf) that you can find here. In that file you will need to make a few changes including the name of the server where Iometer is running, description and device under test address. For example in the icf file change SIOSERVER to the name of the server where you will be running Iometer from. Also change the address for the DUT, for example N: to what ever address, drive, mount point you are using. Also update the description accordingly (e.g. "NVME" to "Your test example".

Here is the command line to run Iometer specifying an icf and where to put the results in a CSV file that can be imported into Excel or other tools.

iometer /c  iometer_5work32q_intel_Profile.icf /r iometer_nvmetest_5work32q_072416_8AM.csv

server storage I/O SCM NVM SSD performance

What About The Results?

For context, the following results were run on a Lenovo TS140 (32GB RAM), single socket quad core (3.2GHz) Intel E3-1225 v3 with an Intel NVMe 750 PCIe AiC (Intel SSDPEDMW40). Out of the box Microsoft Windows NVMe drive and controller drivers were used (e.g. 6.3.9600.18203 and 6.3.9600.16421). Operating system is Windows 2012 R2 (bare metal) with NVMe PCIe card formatted with ReFS file system. Workload generator and benchmark driver tools included Microsoft Diskspd version 2.012, Fio.exe version 2.2.3, Vdbench 50403 and Iometer 1.1.0. Note that there are newer versions of the various workload generation tools.

Example results are located here.

Where To Learn More

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

Remember, everything is not the same in the data center or with data infrastructures that support different applications.

While some tools are more robust or better than others for different things, ultimately its usually not the tool that results in a bad benchmark or comparison, its the configuration or lack of including workload settings that are not relevant or applicable. The best benchmark, workload or simulation is your own application. Second best is one that closely resembles your application workload characteristics. A bad benchmark is one that has no relevance to your environment, application use scenario. Take and treat all benchmark or workload simulation results with a grain of salt as something to compare, contrast or make reference to in the proper context.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

Part 4 – Which HDD for Content Applications – Database Workloads

Part 4 – Which HDD for Content Applications – Database Workloads

data base server storage I/O trends

Updated 1/23/2018
Which enterprise HDD to use with a content server platform for database workloads

Insight for effective server storage I/O decision making
Server StorageIO Lab Review

Which enterprise HDD to use for content servers

This is the fourth in a multi-part series (read part three here) based on a white paper hands-on lab report I did compliments of Servers Direct and Seagate that you can read in PDF form here. The focus is looking at the Servers Direct (www.serversdirect.com) converged Content Solution platforms with Seagate Enterprise Hard Disk Drive (HDD’s). In this post the focus expands to database application workloads that were run to test various HDD’s.

Database Reads/Writes

Transaction Processing Council (TPC) TPC-C like workloads were run against the SUT from the STI. These workloads simulated transactional, content management, meta-data and key-value processing. Microsoft SQL Server 2012 was configured and used with databases (each 470GB e.g. scale 6000) created and workload generated by virtual users via Dell Benchmark Factory (running on STI Windows 2012 R2).

A single SQL Server database instance (8) was used on the SUT, however unique databases were created for each HDD set being tested. Both the main database file (.mdf) and the log file (.ldf) were placed on the same drive set being tested, keep in mind the constraints mentioned above. As time was a constraint, database workloads were run concurrent (9) with each other except for the Enterprise 10K RAID 1 and RAID 10. Workload was run with two 10K HDD’s in a RAID 1 configuration, then another workload run with a four drive RAID 10. In a production environment, ideally the .mdf and .ldf would be placed on separate HDD’s and SSDs.

To improve cache buffering the SQL Server database instance memory could be increased from 16GB to a larger number that would yield higher TPS numbers. Keep in mind the objective was not to see how fast I could make the databases run, rather how the different drives handled the workload.

(Note 8) The SQL Server Tempdb was placed on a separate NVMe flash SSD, also the database instance memory size was set to 16GB which was shared by all databases and virtual users accessing it.

(Note 9) Each user step was run for 90 minutes with a 30 minute warm-up preamble to measure steady-state operation.

Users

TPCC Like TPS

Single Drive Cost per TPS

Drive Cost per TPS

Single Drive Cost / Per GB Raw Cap.

Cost / Per GB Usable (Protected) Cap.

Drive Cost (Multiple Drives)

Protect
Space Over head

Cost per usable GB per TPS

Resp. Time (Sec.)

ENT 15K R1

1

23.9

$24.94

$49.89

$0.99

$0.99

$1,190

100%

$49.89

0.01

ENT 10K R1

1

23.4

$37.38

$74.77

$0.49

$0.49

$1,750

100%

$74.77

0.01

ENT CAP R1

1

16.4

$24.26

$48.52

$0.20

$0.20

$ 798

100%

$48.52

0.03

ENT 10K R10

1

23.2

$37.70

$150.78

$0.49

$0.97

$3,500

100%

$150.78

0.07

ENT CAP SWR5

1

17.0

$23.45

$117.24

$0.20

$0.25

$1,995

20%

$117.24

0.02

ENT 15K R1

20

362.3

$1.64

$3.28

$0.99

$0.99

$1,190

100%

$3.28

0.02

ENT 10K R1

20

339.3

$2.58

$5.16

$0.49

$0.49

$1,750

100%

$5.16

0.01

ENT CAP R1

20

213.4

$1.87

$3.74

$0.20

$0.20

$ 798

100%

$3.74

0.06

ENT 10K R10

20

389.0

$2.25

$9.00

$0.49

$0.97

$3,500

100%

$9.00

0.02

ENT CAP SWR5

20

216.8

$1.84

$9.20

$0.20

$0.25

$1,995

20%

$9.20

0.06

ENT 15K R1

50

417.3

$1.43

$2.85

$0.99

$0.99

$1,190

100%

$2.85

0.08

ENT 10K R1

50

385.8

$2.27

$4.54

$0.49

$0.49

$1,750

100%

$4.54

0.09

ENT CAP R1

50

103.5

$3.85

$7.71

$0.20

$0.20

$ 798

100%

$7.71

0.45

ENT 10K R10

50

778.3

$1.12

$4.50

$0.49

$0.97

$3,500

100%

$4.50

0.03

ENT CAP SWR5

50

109.3

$3.65

$18.26

$0.20

$0.25

$1,995

20%

$18.26

0.42

ENT 15K R1

100

190.7

$3.12

$6.24

$0.99

$0.99

$1,190

100%

$6.24

0.49

ENT 10K R1

100

175.9

$4.98

$9.95

$0.49

$0.49

$1,750

100%

$9.95

0.53

ENT CAP R1

100

59.1

$6.76

$13.51

$0.20

$0.20

$ 798

100%

$13.51

1.66

ENT 10K R10

100

560.6

$1.56

$6.24

$0.49

$0.97

$3,500

100%

$6.24

0.14

ENT CAP SWR5

100

62.2

$6.42

$32.10

$0.20

$0.25

$1,995

20%

$32.10

1.57

Table-2 TPC-C workload results various number of users across different drive configurations

Figure-2 shows TPC-C TPS (red dashed line) workload scaling over various number of users (1, 20, 50, and 100) with peak TPS per drive shown. Also shown is the used space capacity (in green), with total raw storage capacity in blue cross hatch. Looking at the multiple metrics in context shows that the 600GB Enterprise 15K HDD with performance enhanced cache is a premium option as an alternative, or, to complement flash SSD solutions.

database TPCC transactional workloads
Figure-2 472GB Database TPS scaling along with cost per TPS and storage space used

In figure-2, the 1.8TB Enterprise 10K HDD with performance enhanced cache while not as fast as the 15K, provides a good balance of performance, space capacity and cost effectiveness. A good use for the 10K drives is where some amount of performance is needed as well as a large amount of storage space for less frequently accessed content.

A low cost, low performance option would be the 2TB Enterprise Capacity HDD’s that have a good cost per capacity, however lack the performance of the 15K and 10K drives with enhanced performance cache. A four drive RAID 10 along with a five drive software volume (Microsoft WIndows) are also shown. For apples to apples comparison look at costs vs. capacity including number of drives needed for a given level of performance.

Figure-3 is a variation of figure-2 showing TPC-C TPS (blue bar) and response time (red-dashed line) scaling across 1, 20, 50 and 100 users. Once again the Enterprise 15K with enhanced performance cache feature enabled has good performance in an apples to apples RAID 1 comparison.

Note that the best performance was with the four drive RAID 10 using 10K HDD’s Given popularity, a four drive RAID 10 configuration with the 10K drives was used. Not surprising the four 10K drives performed better than the RAID 1 15Ks. Also note using five drives in a software spanned volume provides a large amount of storage capacity and good performance however with a larger drive footprint.

database TPCC transactional workloads scaling
Figure-3 472GB Database TPS scaling along with response time (latency)

From a cost per space capacity perspective, the Enterprise Capacity drives have a good cost per GB. A hybrid solution for environment that do not need ultra-high performance would be to pair a small amount of flash SSD (10) (drives or PCIe cards), as well as the 10K and 15K performance enhanced drives with the Enterprise Capacity HDD (11) along with cache or tiering software.

(Note 10) Refer to Seagate 1200 12 Gbps Enterprise SAS SSD StorageIO lab review

(Note 11) Refer to Enterprise SSHD and Flash SSD Part of an Enterprise Tiered Storage Strategy

Where To Learn More

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

If your environment is using applications that rely on databases, then test resources such as servers, storage, devices using tools that represent your environment. This means moving up the software and technology stack from basic storage I/O benchmark or workload generator tools such as Iometer among others instead using either your own application, or tools that can replay or generate various workloads that represent your environment.

Continue reading part five in this multi-part series here where the focus shifts to large and small file I/O processing workloads.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

Which Enterprise HDD for Content Applications General I/O Performance

Which HDD for Content Applications general I/O Performance

hdd general i/o performance server storage I/O trends

Updated 1/23/2018

Which enterprise HDD to use with a content server platform general I/O performance Insight for effective server storage I/O decision making
Server StorageIO Lab Review

Which enterprise HDD to use for content servers

This is the sixth in a multi-part series (read part five here) based on a white paper hands-on lab report I did compliments of Servers Direct and Seagate that you can read in PDF form here. The focus is looking at the Servers Direct (www.serversdirect.com) converged Content Solution platforms with Seagate Enterprise Hard Disk Drive (HDD’s). In this post the focus is around general I/O performance including 8KB and 128KB IOP sizes.

General I/O Performance

In addition to running database and file (large and small) processing workloads, Vdbench was also used to collect basic small (8KB) and large (128KB) sized I/O operations. This consisted of random and sequential reads as well as writes with the results shown below. In addition to using vdbench, other tools that could be used include Microsoft Diskspd, fio, iorate and iometer among many others.

These workloads used Vdbench configured (13) to do direct I/O to a Windows file system mounted device using as much of the available disk space as possible. All workloads used 16 threads and were run concurrently similar to database and file processing tests.

(Note 13) Sample vdbench configuration for general I/O, note different settings were used for various tests

Table-7 shows workload results for 8KB random IOPs 75% reads and 75% writes including IOPs, bandwidth and response time.

 

ENT 15K RAID1

ENT 10K RAID1

ENT CAP RAID1

ENT 10K R10
(4 Drives)

ECAP SW RAID (5 Drives)

 

75% Read

25% Read

75% Read

25% Read

75% Read

25% Read

75% Read

25% Read

75% Read

25% Read

I/O Rate (IOPs)

597.11

559.26

514

475

285

293

979

984

491

644

MB/sec

4.7

4.4

4.0

3.7

2.2

2.3

7.7

7.7

3.8

5.0

Resp. Time (Sec.)

25.9

27.6

30.2

32.7

55.5

53.7

16.3

16.3

32.6

24.8

Table-7 8KB sized random IOPs workload results

Figure-6 shows small (8KB) random I/O (75% read and 25% read) across different HDD configurations. Performance including activity rates (e.g. IOPs), bandwidth and response time for mixed reads / writes are shown. Note how response time increases with the Enterprise Capacity configurations vs. other performance optimized drives.

general 8K random IO
Figure-6 8KB random reads and write showing IOP activity, bandwidth and response time

Table-8 below shows workload results for 8GB sized I/Os 100% sequential with 75% reads and 75% writes including IOPs, MB/sec and response time in seconds.

ENT 15K RAID1

ENT 10K RAID1

ENT CAP RAID1

ENT 10K R10
(4 Drives)

ECAP SW RAID (5 Drives)

75% Read

25% Read

75% Read

25% Read

75% Read

25% Read

75% Read

25% Read

75% Read

25% Read

I/O Rate (IOPs)

3,778

3,414

3,761

3,986

3,379

1,274

11,840

8,368

2,891

1,146

MB/sec

29.5

26.7

29.4

31.1

26.4

10.0

92.5

65.4

22.6

9.0

Resp. Time (Sec.)

2.2

3.1

2.3

2.4

2.7

10.9

1.3

1.9

5.5

14.0

Table-8 8KB sized sequential workload results

Figure-7 shows small 8KB sequential mixed reads and writes (75% read and 75% write), while the Enterprise Capacity 2TB HDD has a large amount of space capacity, its performance in a RAID 1 vs. other similar configured drives is slower.

8KB Sequential
Figure-7 8KB sequential 75% reads and 75% write showing bandwidth activity

Table-9 shows workload results for 100% sequential, 100% read and 100% write 128KB sized I/Os including IOPs, bandwidth and response time.

ENT 15K RAID1

ENT 10K RAID1

ENT CAP RAID1

ENT 10K R10
(4 Drives)

ECAP SW RAID (5 Drives)

Read

Write

Read

Write

Read

Write

Read

Write

Read

Write

I/O Rate (IOPs)

1,798

1,771

1,716

1,688

921

912

3,552

3,486

780

721

MB/sec

224.7

221.3

214.5

210.9

115.2

114.0

444.0

435.8

97.4

90.1

Resp. Time (Sec.)

8.9

9.0

9.3

9.5

17.4

17.5

4.5

4.6

19.3

20.2

Table-9 128KB sized sequential workload results

Figure-8 shows sequential or streaming operations of larger I/O (100% read and 100% write) requests sizes (128KB) that would be found with large content applications. Figure-8 highlights the relationship between lower response time and increased IOPs as well as bandwidth.

128K Sequential
Figure-8 128KB sequential reads and write showing IOP activity, bandwidth and response time

Where To Learn More

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

Some content applications are doing small random I/Os for database, key value stores or repositories as well as meta data processing while others are doing large sequential I/O. 128KB sized I/O may be large for your environment, on the other hand, with an increasing number of applications, file systems, software defined storage management tools among others, 1 to 10MB or even larger I/O sizes are becoming common. Key is selecting I/O sizes and read write as well as random sequential along with I/O or queue depths that align with your environment.

Continue reading part seven the final post in this multi-part series here where the focus is around how HDD’s continue to evolve including performance beyond traditional RPM based execrations along with wrap up.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

NVMe Need for Performance Speed Performance

server storage I/O trends
Updated 1/12/2018

This is the third in a five-part mini-series providing a primer and overview of NVMe. View companion posts and more material at www.thenvmeplace.com.

How fast is NVMe?

It depends! Generally speaking NVMe is fast!

However fast interfaces and protocols also need fast storage devices, adapters, drivers, servers, operating systems and hypervisors as well as applications that drive or benefit from the increased speed.

A server storage I/O example is in figure 5 where a 6 Gbps SATA NVM flash SSD (left) is shown with an NVMe 8639 (x4) drive that were directly attached to a server. The workload is 8 Kbyte sized random writes with 128 threads (workers) showing results for IOPs (solid bar) along with response time (dotted line). Not surprisingly the NVMe device has a lower response time and a higher number of IOPs. However also note how the amount of CPU time used per IOP is lower on the right with the NVMe drive.

NVMe storage I/O performance
Figure 5 6 Gbps SATA NVM flash SSD vs. NVMe flash SSD

While many people are aware or learning about the IOP and bandwidth improvements as well as the decrease in latency with NVMe, something that gets overlooked is how much less CPU is used. If a server is spending time in wait modes that can result in lost productivity, by finding and removing the barriers more work can be done on a given server, perhaps even delaying a server upgrade.

In figure 5 notice the lower amount of CPU used per work activity being done (e.g. I/O or IOP) which translates to more effective resource use of your server. What that means is either doing more work with what you have, or potentially delaying a CPU server upgrade, or, using those extra CPU cycles to power software defined storage management stacks including erasure coding or advanced parity RAID, replication and other functions.

Table 1 shows relative server I/O performance of some NVM flash SSD devices across various workloads. As with any performance, the comparison takes them, and the following with a grain of salt as your speed will vary.

8KB I/O Size

1MB I/O size

NAND flash SSD

100% Seq. Read

100% Seq. Write

100% Ran. Read

100% Ran. Write

100% Seq. Read

100% Seq. Write

100% Ran. Read

100% Ran. Write

NVMe

IOPs

41829.19

33349.36

112353.6

28520.82

1437.26

889.36

1336.94

496.74

PCIe

Bandwidth

326.79

260.54

877.76

222.82

1437.26

889.36

1336.94

496.74

AiC

Resp.

3.23

3.90

1.30

4.56

178.11

287.83

191.27

515.17

CPU / IOP

0.001571

0.002003

0.000689

0.002342

0.007793

0.011244

0.009798

0.015098

12Gb

IOPs

34792.91

34863.42

29373.5

27069.56

427.19

439.42

416.68

385.9

SAS

Bandwidth

271.82

272.37

229.48

211.48

427.19

429.42

416.68

385.9

Resp.

3.76

3.77

4.56

5.71

599.26

582.66

614.22

663.21

CPU / IOP

0.001857

0.00189

0.002267

0.00229

0.011236

0.011834

0.01416

0.015548

6Gb

IOPs

33861.29

9228.49

28677.12

6974.32

363.25

65.58

356.06

55.86

SATA

Bandwidth

264.54

72.1

224.04

54.49

363.25

65.58

356.06

55.86

Resp.

4.05

26.34

4.67

35.65

704.70

3838.59

718.81

4535.63

CPU / IOP

0.001899

0.002546

0.002298

0.003269

0.012113

0.032022

0.015166

0.046545

Table 1 Relative performance of various protocols and interfaces

The workload results in table 1 were generated using a vdbench script running on a Windows 2012 R2 based server and are intended to be a relative indicator of different protocol and interfaces; your performance mileage will vary. The results shown below compare the number of IOPs (activity rate) for reads, writes, random and sequential across small 8KB and large 1MB sized I/Os.

Also shown in table 1 are bandwidth or throughput (e.g. amount of data moved), response time and the amount of CPU used per IOP. Note in table 1 how NVMe can do higher IOPs with a lower CPU per IOP, or, using a similar amount of CPU, do more work at a lower latency. SSD has been used for decades to help reduce CPU bottlenecks or defer server upgrades by removing I/O wait times and reduce CPU consumption (e.g. wait or lost time).

Can NVMe solutions run faster than those shown above? Absolutely!

Where To Learn More

View additional NVMe, SSD, NVM, SCM, Data Infrastructure and related topics via the following links.

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

Continue reading about NVMe with Part IV (Where and How to use NVMe) in this five-part series, or jump to Part I, Part II or Part V.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

Big Files Lots of Little File Processing Benchmarking with Vdbench

Big Files Lots of Little File Processing Benchmarking with Vdbench


server storage data infrastructure i/o File Processing Benchmarking with Vdbench

Updated 2/10/2018

Need to test a server, storage I/O networking, hardware, software, services, cloud, virtual, physical or other environment that is either doing some form of file processing, or, that you simply want to have some extra workload running in the background for what ever reason? An option is File Processing Benchmarking with Vdbench.

I/O performance

Getting Started


Here’s a quick and relatively easy way to do it with Vdbench (Free from Oracle). Granted there are other tools, both for free and for fee that can similar things, however we will leave those for another day and post. Here’s the con to this approach, there is no Uui Gui like what you have available with some other tools Here’s the pro to this approach, its free, flexible and limited by your creative, amount of storage space, server memory and I/O capacity.

If you need a background on Vdbench and benchmarking, check out the series of related posts here (e.g. www.storageio.com/performance).

Get and Install the Vdbench Bits and Bytes


If you do not already have Vdbench installed, get a copy from the Oracle or Source Forge site (now points to Oracle here).

Vdbench is free, you simply sign-up and accept the free license, select the version down load (it is a single, common distribution for all OS) the bits as well as documentation.

Installation particular on Windows is really easy, basically follow the instructions in the documentation by copying the contents of the download folder to a specified directory, set up any environment variables, and make sure that you have Java installed.

Here is a hint and tip for Windows Servers, if you get an error message about counters, open a command prompt with Administrator rights, and type the command:

$ lodctr /r


The above command will reset your I/O counters. Note however that command will also overwrite counters if enabled so only use it if you have to.

Likewise *nix install is also easy, copy the files, make sure to copy the applicable *nix shell script (they are in the download folder), and verify Java is installed and working.

You can do a vdbench -t (windows) or ./vdbench -t (*nix) to verify that it is working.

Vdbench File Processing

There are many options with Vdbench as it has a very robust command and scripting language including ability to set up for loops among other things. We are only going to touch the surface here using its file processing capabilities. Likewise, Vdbench can run from a single server accessing multiple storage systems or file systems, as well as running from multiple servers to a single file system. For simplicity, we will stick with the basics in the following examples to exercise a local file system. The limits on the number of files and file size are limited by server memory and storage space.

You can specify number and depth of directories to put files into for processing. One of the parameters is the anchor point for the file processing, in the following examples =S:\SIOTEMP\FS1 is used as the anchor point. Other parameters include the I/O size, percent reads, number of threads, run time and sample interval as well as output folder name for the result files. Note that unlike some tools, Vdbench does not create a single file of results, rather a folder with several files including summary, totals, parameters, histograms, CSV among others.


Simple Vdbench File Processing Commands

For flexibility and ease of use I put the following three Vdbench commands into a simple text file that is then called with parameters on the command line.
fsd=fsd1,anchor=!fanchor,depth=!dirdep,width=!dirwid,files=!numfiles,size=!filesize

fwd=fwd1,fsd=fsd1,rdpct=!filrdpct,xfersize=!fxfersize,fileselect=random,fileio=random,threads=!thrds

rd=rd1,fwd=fwd1,fwdrate=max,format=yes,elapsed=!etime,interval=!itime

Simple Vdbench script

# SIO_vdbench_filesystest.txt
#
# Example Vdbench script for file processing
#
# fanchor = file system place where directories and files will be created
# dirwid = how wide should the directories be (e.g. how many directories wide)
# numfiles = how many files per directory
# filesize = size in in k, m, g e.g. 16k = 16KBytes
# fxfersize = file I/O transfer size in kbytes
# thrds = how many threads or workers
# etime = how long to run in minutes (m) or hours (h)
# itime = interval sample time e.g. 30 seconds
# dirdep = how deep the directory tree
# filrdpct = percent of reads e.g. 90 = 90 percent reads
# -p processnumber = optional specify a process number, only needed if running multiple vdbenchs at same time, number should be unique
# -o output file that describes what being done and some config info
#
# Sample command line shown for Windows, for *nix add ./
#
# The real Vdbench script with command line parameters indicated by !=
#

fsd=fsd1,anchor=!fanchor,depth=!dirdep,width=!dirwid,files=!numfiles,size=!filesize

fwd=fwd1,fsd=fsd1,rdpct=!filrdpct,xfersize=!fxfersize,fileselect=random,fileio=random,threads=!thrds

rd=rd1,fwd=fwd1,fwdrate=max,format=yes,elapsed=!etime,interval=!itime

Big Files Processing Script


With the above script file defined, for Big Files I specify a command line such as the following.
$ vdbench -f SIO_vdbench_filesystest.txt fanchor=S:\SIOTemp\FS1 dirwid=1 numfiles=60 filesize=5G fxfersize=128k thrds=64 etime=10h itime=30 numdir=1 dirdep=1 filrdpct=90 -p 5576 -o SIOWS2012R220_NOFUZE_5Gx60_BigFiles_64TH_STX1200_020116

Big Files Processing Example Results


The following is one of the result files from the folder of results created via the above command for Big File processing showing totals.


Run totals

21:09:36.001 Starting RD=format_for_rd1

Feb 01, 2016 .Interval. .ReqstdOps.. ...cpu%... read ....read.... ...write.... ..mb/sec... mb/sec .xfer.. ...mkdir... ...rmdir... ..create... ...open.... ...close... ..delete...
rate resp total sys pct rate resp rate resp read write total size rate resp rate resp rate resp rate resp rate resp rate resp
21:23:34.101 avg_2-28 2848.2 2.70 8.8 8.32 0.0 0.0 0.00 2848.2 2.70 0.00 356.0 356.02 131071 0.0 0.00 0.0 0.00 0.1 109176 0.1 0.55 0.1 2006 0.0 0.00

21:23:35.009 Starting RD=rd1; elapsed=36000; fwdrate=max. For loops: None

07:23:35.000 avg_2-1200 4939.5 1.62 18.5 17.3 90.0 4445.8 1.79 493.7 0.07 555.7 61.72 617.44 131071 0.0 0.00 0.0 0.00 0.0 0.00 0.1 0.03 0.1 2.95 0.0 0.00


Lots of Little Files Processing Script


For lots of little files, the following is used.


$ vdbench -f SIO_vdbench_filesystest.txt fanchor=S:\SIOTEMP\FS1 dirwid=64 numfiles=25600 filesize=16k fxfersize=1k thrds=64 etime=10h itime=30 dirdep=1 filrdpct=90 -p 5576 -o SIOWS2012R220_NOFUZE_SmallFiles_64TH_STX1200_020116

Lots of Little Files Processing Example Results


The following is one of the result files from the folder of results created via the above command for Big File processing showing totals.
Run totals

09:17:38.001 Starting RD=format_for_rd1

Feb 02, 2016 .Interval. .ReqstdOps.. ...cpu%... read ....read.... ...write.... ..mb/sec... mb/sec .xfer.. ...mkdir... ...rmdir... ..create... ...open.... ...close... ..delete...
rate resp total sys pct rate resp rate resp read write total size rate resp rate resp rate resp rate resp rate resp rate resp
09:19:48.016 avg_2-5 10138 0.14 75.7 64.6 0.0 0.0 0.00 10138 0.14 0.00 158.4 158.42 16384 0.0 0.00 0.0 0.00 10138 0.65 10138 0.43 10138 0.05 0.0 0.00

09:19:49.000 Starting RD=rd1; elapsed=36000; fwdrate=max. For loops: None

19:19:49.001 avg_2-1200 113049 0.41 67.0 55.0 90.0 101747 0.19 11302 2.42 99.36 11.04 110.40 1023 0.0 0.00 0.0 0.00 0.0 0.00 7065 0.85 7065 1.60 0.0 0.00


Where To Learn More

View additional NAS, NVMe, SSD, NVM, SCM, Data Infrastructure and HDD related topics via the following links.

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

The above examples can easily be modified to do different things particular if you read the Vdbench documentation on how to setup multi-host, multi-storage system, multiple job streams to do different types of processing. This means you can benchmark a storage systems, server or converged and hyper-converged platform, or simply put a workload on it as part of other testing. There are even options for handling data footprint reduction such as compression and dedupe.

Ok, nuff said, for now.

Gs

Greg Schulz - Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

NVMe Place NVM Non Volatile Memory Express Resources

Updated 8/31/19
NVMe place server Storage I/O data infrastructure trends

Welcome to NVMe place NVM Non Volatile Memory Express Resources. NVMe place is about Non Volatile Memory (NVM) Express (NVMe) with Industry Trends Perspectives, Tips, Tools, Techniques, Technologies, News and other information.

Disclaimer

Please note that this NVMe place resources site is independent of the industry trade and promoters group NVM Express, Inc. (e.g. www.nvmexpress.org). NVM Express, Inc. is the sole owner of the NVM Express specifications and trademarks.

NVM Express Organization
Image used with permission of NVM Express, Inc.

Visit the NVM Express industry promoters site here to learn more about their members, news, events, product information, software driver downloads, and other useful NVMe resources content.

 

The NVMe Place resources and NVM including SCM, PMEM, Flash

NVMe place includes Non Volatile Memory (NVM) including nand flash, storage class memories (SCM), persistent memories (PM) are storage memory mediums while NVM Express (NVMe) is an interface for accessing NVM. This NVMe resources page is a companion to The SSD Place which has a broader Non Volatile Memory (NVM) focus including flash among other SSD topics. NVMe is a new server storage I/O access method and protocol for fast access to NVM based storage and memory technologies. NVMe is an alternative to existing block based server storage I/O access protocols such as AHCI/SATA and SCSI/SAS devices commonly used for access Hard Disk Drives (HDD) along with SSD among other things.

Server Storage I/O NVMe PCIe SAS SATA AHCI
Comparing AHCI/SATA, SCSI/SAS and NVMe all of which can coexist to address different needs.

Leveraging the standard PCIe hardware interface, NVMe based devices (that have an NVMe controller) can be accessed via various operating systems (and hypervisors such as VMware ESXi) with both in the box drivers or optional third-party device drivers. Devices that support NVMe can be 2.5″ drive format packaged that use a converged 8637/8639 connector (e.g. PCIe x4) coexisting with SAS and SATA devices as well as being add-in card (AIC) PCIe cards supporting x4, x8 and other implementations. Initially, NVMe is being positioned as a back-end to servers (or storage systems) interface for accessing fast flash and other NVM based devices.

NVMe as back-end storage
NVMe as a “back-end” I/O interface for NVM storage media

NVMe as front-end server storage I/O interface
NVMe as a “front-end” interface for servers or storage systems/appliances

NVMe has also been shown to work over low latency, high-speed RDMA based network interfaces including RoCE (RDMA over Converged Ethernet) and InfiniBand (read more here, here and here involving Mangstor, Mellanox and PMC among others). What this means is that like SCSI based SAS which can be both a back-end drive (HDD, SSD, etc) access protocol and interface, NVMe can also being used for back-end can also be used as a front-end of server to storage interface like how Fibre Channel SCSI_Protocol (aka FCP), SCSI based iSCSI, SCSI RDMA Protocol via InfiniBand (among others) are used.

NVMe features

Main features of NVMe include among others:

  • Lower latency due to improve drivers and increased queues (and queue sizes)
  • Lower CPU used to handle larger number of I/Os (more CPU available for useful work)
  • Higher I/O activity rates (IOPs) to boost productivity unlock value of fast flash and NVM
  • Bandwidth improvements leveraging various fast PCIe interface and available lanes
  • Dual-pathing of devices like what is available with dual-path SAS devices
  • Unlock the value of more cores per processor socket and software threads (productivity)
  • Various packaging options, deployment scenarios and configuration options
  • Appears as a standard storage device on most operating systems
  • Plug-play with in-box drivers on many popular operating systems and hypervisors

Shared external PCIe using NVMe
NVMe and shared PCIe (e.g. shared PCIe flash DAS)

NVMe related content and links

The following are some of my tips, articles, blog posts, presentations and other content, along with material from others pertaining to NVMe. Keep in mind that the question should not be if NVMe is in your future, rather when, where, with what, from whom and how much of it will be used as well as how it will be used.

  • How to Prepare for the NVMe Server Storage I/O Wave (Via Micron.com)
  • Why NVMe Should Be in Your Data Center (Via Micron.com)
  • NVMe U2 (8639) vs. M2 interfaces (Via Gamersnexus)
  • Enmotus FuzeDrive MicroTiering (StorageIO Lab Report)
  • EMC DSSD D5 Rack Scale Direct Attached Shared SSD All Flash Array Part I (Via StorageIOBlog)
  • Part II – EMC DSSD D5 Direct Attached Shared AFA (Via StorageIOBlog)
  • NAND, DRAM, SAS/SCSI & SATA/AHCI: Not Dead, Yet! (Via EnterpriseStorageForum)
  • Non Volatile Memory (NVM), NVMe, Flash Memory Summit and SSD updates (Via StorageIOblog)
  • Microsoft and Intel showcase Storage Spaces Direct with NVM Express at IDF ’15 (Via TechNet)
  • MNVM Express solutions (Via SuperMicro)
  • Gaining Server Storage I/O Insight into Microsoft Windows Server 2016 (Via StorageIOblog)
  • PMC-Sierra Scales Storage with PCIe, NVMe (Via EEtimes)
  • RoCE updates among other items (Via InfiniBand Trade Association (IBTA) December Newsletter)
  • NVMe: The Golden Ticket for Faster Flash Storage? (Via EnterpriseStorageForum)
  • What should I consider when using SSD cloud? (Via SearchCloudStorage)
  • MSP CMG, Sept. 2014 Presentation (Flash back to reality – Myths and Realities – Flash and SSD Industry trends perspectives plus benchmarking tips)– PDF
  • Selecting Storage: Start With Requirements (Via NetworkComputing)
  • PMC Announces Flashtec NVMe SSD NVMe2106, NVMe2032 Controllers With LDPC (Via TomsITpro)
  • Exclusive: If Intel and Micron’s “Xpoint” is 3D Phase Change Memory, Boy Did They Patent It (Via Dailytech)
  • Intel & Micron 3D XPoint memory — is it just CBRAM hyped up? Curation of various posts (Via Computerworld)
  • How many IOPS can a HDD, HHDD or SSD do (Part I)?
  • How many IOPS can a HDD, HHDD or SSD do with VMware? (Part II)
  • I/O Performance Issues and Impacts on Time-Sensitive Applications (Via CMG)
  • Via EnterpriseStorageForum: 5 Hot Storage Technologies to Watch
  • Via EnterpriseStorageForum: 10-Year Review of Data Storage

Non-Volatile Memory (NVM) Express (NVMe) continues to evolve as a technology for enabling and improving server storage I/O for NVM including nand flash SSD storage. NVMe streamline performance enabling more work to be done (e.g. IOPs), data to be moved (bandwidth) at a lower response time using less CPU.

NVMe and SATA flash SSD performance

The above figure is a quick look comparing nand flash SSD being accessed via SATA III (6Gbps) on the left and NVMe (x4) on the right. As with any server storage I/O performance comparisons there are many variables and take them with a grain of salt. While IOPs and bandwidth are often discussed, keep in mind that with the new protocol, drivers and device controllers with NVMe that streamline I/O less CPU is needed.

Additional NVMe Resources

Also check out the Server StorageIO companion micro sites landing pages including thessdplace.com (SSD focus), data protection diaries (backup, BC/DR/HA and related topics), cloud and object storage, and server storage I/O performance and benchmarking here.

If you are in to the real bits and bytes details such as at device driver level content check out the Linux NVMe reflector forum. The linux-nvme forum is a good source if you are developer to stay up on what is happening in and around device driver and associated topics.

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

Disclaimer

Disclaimer: Please note that this site is independent of the industry trade and promoters group NVM Express, Inc. (e.g. www.nvmexpress.org). NVM Express, Inc. is the sole owner of the NVM Express specifications and trademarks. Check out the NVM Express industry promoters site here to learn more about their members, news, events, product information, software driver downloads, and other useful NVMe resources content.

NVM Express Organization
Image used with permission of NVM Express, Inc.

Wrap Up

Watch for updates with more content, links and NVMe resources to be added here soon.

Ok, nuff said (for now)

Cheers
Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

How to test your HDD SSD or all flash array (AFA) storage fundamentals

How to test your HDD SSD AFA Hybrid or cloud storage

server storage data infrastructure i/o hdd ssd all flash array afa fundamentals

Updated 2/14/2018

Over at BizTech Magazine I have a new article 4 Ways to Performance Test Your New HDD or SSD that provides a quick guide to verifying or learning what the speed characteristic of your new storage device are capable of.

An out-take from the article used by BizTech as a "tease" is:

These four steps will help you evaluate new storage drives. And … psst … we included the metrics that matter.

Building off the basics, server storage I/O benchmark fundamentals

The four basic steps in the article are:

  • Plan what and how you are going to test (what’s applicable for you)
  • Decide on a benchmarking tool (learn about various tools here)
  • Test the test (find bugs, errors before a long running test)
  • Focus on metrics that matter (what’s important for your environment)

Server Storage I/O performance

Where To Learn More

View additional NAS, NVMe, SSD, NVM, SCM, Data Infrastructure and HDD related topics via the following links.

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

To some the above (read the full article here) may seem like common sense tips and things everybody should know otoh there are many people who are new to servers storage I/O networking hardware software cloud virtual along with various applications, not to mention different tools.

Thus the above is a refresher for some (e.g. Dejavu) while for others it might be new and revolutionary or simply helpful. Interested in HDD’s, SSD’s as well as other server storage I/O performance along with benchmarking tools, techniques and trends check out the collection of links here (Server and Storage I/O Benchmarking and Performance Resources).

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

Server Storage I/O Benchmark Performance Resource Tools

Server Storage I/O Benchmarking Performance Resource Tools

server storage I/O trends

Updated 1/23/2018

Server storage I/O benchmark performance resource tools, various articles and tips. These include tools for legacy, virtual, cloud and software defined environments.

benchmark performance resource tools server storage I/O performance

The best server and storage I/O (input/output operation) is the one that you do not have to do, the second best is the one with the least impact.

server storage I/O locality of reference

This is where the idea of locality of reference (e.g. how close is the data to where your application is running) comes into play which is implemented via tiered memory, storage and caching shown in the figure above.

Cloud virtual software defined storage I/O

Server storage I/O performance applies to cloud, virtual, software defined and legacy environments

What this has to do with server storage I/O (and networking) performance benchmarking is keeping the idea of locality of reference, context and the application workload in perspective regardless of if cloud, virtual, software defined or legacy physical environments.

StorageIOblog: I/O, I/O how well do you know about good or bad server and storage I/Os?
StorageIOblog: Server and Storage I/O benchmarking 101 for smarties
StorageIOblog: Which Enterprise HDDs to use for a Content Server Platform (7 part series with using benchmark tools)
StorageIO.com: Enmotus FuzeDrive MicroTiering lab test using various tools
StorageIOblog: Some server storage I/O benchmark tools, workload scripts and examples (Part I) and (Part II)
StorageIOblog: Get in the NVMe SSD game (if you are not already)
Doridmen.com: Transcend SSD360S Review with tips on using ATTO and Crystal benchmark tools
ComputerWeekly: Storage performance metrics: How suppliers spin performance specifications

Via StorageIO Podcast: Kevin Closson discusses SLOB Server CPU I/O Database Performance benchmarks
Via @KevinClosson: SLOB Use Cases By Industry Vendors. Learn SLOB, Speak The Experts’ Language
Via BeyondTheBlocks (Reduxio): 8 Useful Tools for Storage I/O Benchmarking
Via CCSIObench: Cold-cache Sequential I/O Benchmark
Doridmen.com: Transcend SSD360S Review with tips on using ATTO and Crystal benchmark tools
CISJournal: Benchmarking the Performance of Microsoft Hyper-V server, VMware ESXi and Xen Hypervisors (PDF)
Microsoft TechNet:Windows Server 2016 Hyper-V large-scale VM performance for in-memory transaction processing
InfoStor: What’s The Best Storage Benchmark?
StorageIOblog: How to test your HDD, SSD or all flash array (AFA) storage fundamentals
Via ATTO: Atto V3.05 free storage test tool available
Via StorageIOblog: Big Files and Lots of Little File Processing and Benchmarking with Vdbench

Via StorageIO.com: Which Enterprise Hard Disk Drives (HDDs) to use with a Content Server Platform (White Paper)
Via VMware Blogs: A Free Storage Performance Testing Tool For Hyperconverged
Microsoft Technet: Test Storage Spaces Performance Using Synthetic Workloads in Windows Server
Microsoft Technet: Microsoft Windows Server Storage Spaces – Designing for Performance
BizTech: 4 Ways to Performance-Test Your New HDD or SSD
EnterpriseStorageForum: Data Storage Benchmarking Guide
StorageSearch.com: How fast can your SSD run backwards?
OpenStack: How to calculate IOPS for Cinder Storage ?
StorageAcceleration: Tips for Measuring Your Storage Acceleration

server storage I/O STI and SUT

Spiceworks: Determining HDD SSD SSHD IOP Performance
Spiceworks: Calculating IOPS from Perfmon data
Spiceworks: profiling IOPs

vdbench server storage I/O benchmark
Vdbench example via StorageIOblog.com

StorageIOblog: What does server storage I/O scaling mean to you?
StorageIOblog: What is the best kind of IO? The one you do not have to do
Testmyworkload.com: Collect and report various OS workloads
Whoishostingthis: Various SQL resources
StorageAcceleration: What, When, Why & How to Accelerate Storage
Filesystems.org: Various tools and links
StorageIOblog: Can we get a side of context with them IOPS and other storage metrics?

flash ssd and hdd

BrightTalk Webinar: Data Center Monitoring – Metrics that Matter for Effective Management
StorageIOblog: Enterprise SSHD and Flash SSD Part of an Enterprise Tiered Storage Strategy
StorageIOblog: Has SSD put Hard Disk Drives (HDD’s) On Endangered Species List?

server storage I/O bottlenecks and I/O blender

Microsoft TechNet: Measuring Disk Latency with Windows Performance Monitor (Perfmon)
Via Scalegrid.io: How to benchmark MongoDB with YCSB? (Perfmon)
Microsoft MSDN: List of Perfmon counters for sql server
Microsoft TechNet: Taking Your Server’s Pulse
StorageIOblog: Part II: How many IOPS can a HDD, HHDD or SSD do with VMware?
CMG: I/O Performance Issues and Impacts on Time-Sensitive Applications

flash ssd and hdd

Virtualization Practice: IO IO it is off to Storage and IO metrics we go
InfoStor: Is HP Short Stroking for Performance and Capacity Gains?
StorageIOblog: Is Computer Data Storage Complex? It Depends
StorageIOblog: More storage and IO metrics that matter
StorageIOblog: Moving Beyond the Benchmark Brouhaha
Yellow-Bricks: VSAN VDI Benchmarking and Beta refresh!

server storage I/O benchmark example

YellowBricks: VSAN performance: many SAS low capacity VS some SATA high capacity?
YellowBricsk: VSAN VDI Benchmarking and Beta refresh!
StorageIOblog: Seagate 1200 12Gbs Enterprise SAS SSD StorgeIO lab review
StorageIOblog: Part II: Seagate 1200 12Gbs Enterprise SAS SSD StorgeIO lab review
StorageIOblog: Server Storage I/O Network Benchmark Winter Olympic Games

flash ssd and hdd

VMware VDImark aka View Planner (also here, here and here) as well as VMmark here
StorageIOblog: SPC and Storage Benchmarking Games
StorageIOblog: Speaking of speeding up business with SSD storage
StorageIOblog: SSD and Storage System Performance

Hadoop server storage I/O performance
Various Server Storage I/O tools in a hadoop environment

Michael-noll.com: Benchmarking and Stress Testing an Hadoop Cluster With TeraSort, TestDFSIO
Virtualization Practice: SSD options for Virtual (and Physical) Environments Part I: Spinning up to speed on SSD
StorageIOblog: Storage and IO metrics that matter
InfoStor: Storage Metrics and Measurements That Matter: Getting Started
SilvertonConsulting: Storage throughput vs. IO response time and why it matters
Splunk: The percentage of Read / Write utilization to get to 800 IOPS?

flash ssd and hdd
Various server storage I/O benchmarking tools

Spiceworks: What is the best IO IOPs testing tool out there
StorageIOblog: How many IOPS can a HDD, HHDD or SSD do?
StorageIOblog: Some Windows Server Storage I/O related commands
Openmaniak: Iperf overview and Iperf.fr: Iperf overview
StorageIOblog: Server and Storage I/O Benchmark Tools: Microsoft Diskspd (Part I and Part II)
Quest: SQL Server Perfmon Poster (PDF)
Server and Storage I/O Networking Performance Management (webinar)
Data Center Monitoring – Metrics that Matter for Effective Management (webinar)
Flash back to reality – Flash SSD Myths and Realities (Industry trends & benchmarking tips), (MSP CMG presentation)
DBAstackexchange: How can I determine how many IOPs I need for my AWS RDS database?
ITToolbox: Benchmarking the Performance of SANs

server storage IO labs

StorageIOblog: Dell Inspiron 660 i660, Virtual Server Diamond in the rough (Server review)
StorageIOblog: Part II: Lenovo TS140 Server and Storage I/O Review (Server review)
StorageIOblog: DIY converged server software defined storage on a budget using Lenovo TS140
StorageIOblog: Server storage I/O Intel NUC nick knack notes First impressions (Server review)
StorageIOblog & ITKE: Storage performance needs availability, availability needs performance
StorageIOblog: Why SSD based arrays and storage appliances can be a good idea (Part I)
StorageIOblog: Revisiting RAID storage remains relevant and resources

Interested in cloud and object storage visit our objectstoragecenter.com page, for flash SSD checkout storageio.com/ssd page, along with data protection, RAID, various industry links and more here.

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

Watch for additional links to be added above in addition to those that appear via comments.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

I/O, I/O how well do you know good bad ugly server storage I/O iops?

How well do you know good bad ugly I/O iops?

server storage i/o iops activity data infrastructure trends

Updated 2/10/2018

There are many different types of server storage I/O iops associated with various environments, applications and workloads. Some I/Os activity are iops, others are transactions per second (TPS), files or messages per time (hour, minute, second), gets, puts or other operations. The best IO is one you do not have to do.

What about all the cloud, virtual, software defined and legacy based application that still need to do I/O?

If no IO operation is the best IO, then the second best IO is the one that can be done as close to the application and processor as possible with the best locality of reference.

Also keep in mind that aggregation (e.g. consolidation) can cause aggravation (server storage I/O performance bottlenecks).

aggregation causes aggravation
Example of aggregation (consolidation) causing aggravation (server storage i/o blender bottlenecks)

And the third best?

It’s the one that can be done in less time or at least cost or effect to the requesting application, which means moving further down the memory and storage stack.

solving server storage i/o blender and other bottlenecks
Leveraging flash SSD and cache technologies to find and fix server storage I/O bottlenecks

On the other hand, any IOP regardless of if for block, file or object storage that involves some context is better than those without, particular involving metrics that matter (here, here and here [webinar] )

Server Storage I/O optimization and effectiveness

The problem with IO’s is that they are a basic operations to get data into and out of a computer or processor, so there’s no way to avoid all of them, unless you have a very large budget. Even if you have a large budget that can afford an all flash SSD solution, you may still meet bottlenecks or other barriers.

IO’s require CPU or processor time and memory to set up and then process the results as well as IO and networking resources to move data too their destination or retrieve them from where they are stored. While IO’s cannot be eliminated, their impact can be greatly improved or optimized by, among other techniques, doing fewer of them via caching and by grouping reads or writes (pre-fetch, write-behind).

server storage I/O STI and SUT

Think of it this way: Instead of going on multiple errands, sometimes you can group multiple destinations together making for a shorter, more efficient trip. However, that optimization may also mean your drive will take longer. So, sometimes it makes sense to go on a couple of quick, short, low-latency trips instead of one larger one that takes half a day even as it accomplishes many tasks. Of course, how far you have to go on those trips (i.e., their locality) makes a difference about how many you can do in a given amount of time.

Locality of reference (or proximity)

What is locality of reference?

This refers to how close (i.e., its place) data exists to where it is needed (being referenced) for use. For example, the best locality of reference in a computer would be registers in the processor core, ready to be acted on immediately. This would be followed by levels 1, 2, and 3 (L1, L2, and L3) onboard caches, followed by main memory, or DRAM. After that comes solid-state memory typically NAND flash either on PCIe cards or accessible on a direct attached storage (DAS), SAN, or NAS device. 

server storage I/O locality of reference

Even though a PCIe NAND flash card is close to the processor, there still remains the overhead of traversing the PCIe bus and associated drivers. To help offset that impact, PCIe cards use DRAM as cache or buffers for data along with meta or control information to further optimize and improve locality of reference. In other words, this information is used to help with cache hits, cache use, and cache effectiveness vs. simply boosting cache use.

SSD to the rescue?

What can you do the cut the impact of IO’s?

There are many steps one can take, starting with establishing baseline performance and availability metrics.

The metrics that matter include IOP’s, latency, bandwidth, and availability. Then, leverage metrics to gain insight into your application’s performance.

Understand that IO’s are a fact of applications doing work (storing, retrieving, managing data) no matter whether systems are virtual, physical, or running up in the cloud. But it’s important to understand just what a bad IO is, along with its impact on performance. Try to identify those that are bad, and then find and fix the problem, either with software, application, or database changes. Perhaps you need to throw more software caching tools, hypervisors, or hardware at the problem. Hardware may include faster processors with more DRAM and faster internal busses.

Leveraging local PCIe flash SSD cards for caching or as targets is another option.

You may want to use storage systems or appliances that rely on intelligent caching and storage optimization capabilities to help with performance, availability, and capacity.

Where to gain insight into your server storage I/O environment

There are many tools that you can be used to gain insight into your server storage I/O environment across cloud, virtual, software defined and legacy as well as from different layers (e.g. applications, database, file systems, operating systems, hypervisors, server, storage, I/O networking). Many applications along with databases have either built-in or optional tools from their provider, third-party, or via other sources that can give information about work activity being done. Likewise there are tools to dig down deeper into the various data information infrastructure to see what is happening at the various layers as shown in the following figures.

application storage I/O performance
Gaining application and operating system level performance insight via different tools

windows and linux storage I/O performance
Insight and awareness via operating system tools on Windows and Linux

In the above example, Spotlight on Windows (SoW) which you can download for free from Dell here along with Ubuntu utilities are shown, You could also use other tools to look at server storage I/O performance including Windows Perfmon among others.

vmware server storage I/O
Hypervisor performance using VMware ESXi / vsphere built-in tools

vmware server storage I/O performance
Using Visual ESXtop to dig deeper into virtual server storage I/O performance

vmware server storage i/o cache
Gaining insight into virtual server storage I/O cache performance

Wrap up and summary

There are many approaches to address (e.g. find and fix) vs. simply move or mask data center and server storage I/O bottlenecks. Having insight and awareness into how your environment along with applications is important to know to focus resources. Also keep in mind that a bit of flash SSD or DRAM cache in the applicable place can go along way while a lot of cache will also cost you cash. Even if you cant eliminate I/Os, look for ways to decrease their impact on your applications and systems.

Where To Learn More

View additional NAS, NVMe, SSD, NVM, SCM, Data Infrastructure and HDD related topics via the following links.

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

>Keep in mind: SSD including flash and DRAM among others are in your future, the question is where, when, with what, how much and whose technology or packaging.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

Revisiting RAID data protection remains relevant resource links

Revisiting RAID data protection remains relevant and resources

Storage I/O trends

Updated 2/10/2018

RAID data protection remains relevant including erasure codes (EC), local reconstruction codes (LRC) among other technologies. If RAID were really not relevant anymore (e.g. actually dead), why do some people spend so much time trying to convince others that it is dead or to use a different RAID level or enhanced RAID or beyond raid with related advanced approaches?

When you hear RAID, what comes to mind?

A legacy monolithic storage system that supports narrow 4, 5 or 6 drive wide stripe sets or a modern system support dozens of drives in a RAID group with different options?

RAID means many things, likewise there are different implementations (hardware, software, systems, adapters, operating systems) with various functionality, some better than others.

For example, which of the items in the following figure come to mind, or perhaps are new to your RAID vocabulary?

RAID questions

There are Many Variations of RAID Storage some for the enterprise, some for SMB, SOHO or consumer. Some have better performance than others, some have poor performance for example causing extra writes that lead to the perception that all parity based RAID do extra writes (some actually do write gathering and optimization).

Some hardware and software implementations using WBC (write back cache) mirrored or battery backed-BBU along with being able to group writes together in memory (cache) to do full stripe writes. The result can be fewer back-end writes compared to other systems. Hence, not all RAID implementations in either hardware or software are the same. Likewise, just because a RAID definition shows a particular theoretical implementation approach does not mean all vendors have implemented it in that way.

RAID is not a replacement for backup rather part of an overall approach to providing data availability and accessibility.

data protection and durability

What’s the best RAID level? The one that meets YOUR needs

There are different RAID levels and implementations (hardware, software, controller, storage system, operating system, adapter among others) for various environments (enterprise, SME, SMB, SOHO, consumer) supporting primary, secondary, tertiary (backup/data protection, archiving).

RAID comparison
General RAID comparisons

Thus one size or approach does fit all solutions, likewise RAID rules of thumbs or guides need context. Context means that a RAID rule or guide for consumer or SOHO or SMB might be different for enterprise and vise versa, not to mention on the type of storage system, number of drives, drive type and capacity among other factors.

RAID comparison
General basic RAID comparisons

Thus the best RAID level is the one that meets your specific needs in your environment. What is best for one environment and application may be different from what is applicable to your needs.

Key points and RAID considerations include:

· Not all RAID implementations are the same, some are very much alive and evolving while others are in need of a rest or rewrite. So it is not the technology or techniques that are often the problem, rather how it is implemented and then deployed.

· It may not be RAID that is dead, rather the solution that uses it, hence if you think a particular storage system, appliance, product or software is old and dead along with its RAID implementation, then just say that product or vendors solution is dead.

· RAID can be implemented in hardware controllers, adapters or storage systems and appliances as well as via software and those have different features, capabilities or constraints.

· Long or slow drive rebuilds are a reality with larger disk drives and parity-based approaches; however, you have options on how to balance performance, availability, capacity, and economics.

· RAID can be single, dual or multiple parity or mirroring-based.

· Erasure and other coding schemes leverage parity schemes and guess what umbrella parity schemes fall under.

· RAID may not be cool, sexy or a fun topic and technology to talk about, however many trendy tools, solutions and services actually use some form or variation of RAID as part of their basic building blocks. This is an example of using new and old things in new ways to help each other do more without increasing complexity.

·  Even if you are not a fan of RAID and think it is old and dead, at least take a few minutes to learn more about what it is that you do not like to update your dead FUD.

Wait, Isn’t RAID dead?

There is some dead marketing that paints a broad picture that RAID is dead to prop up something new, which in some cases may be a derivative variation of parity RAID.

data dispersal
Data dispersal and durability

RAID rebuild improving
RAID continues to evolve with rapid rebuilds for some systems

Otoh, there are some specific products, technologies, implementations that may be end of life or actually dead. Likewise what might be dead, dying or simply not in vogue are specific RAID implementations or packaging. Certainly there is a lot of buzz around object storage, cloud storage, forward error correction (FEC) and erasure coding including messages of how they cut RAID. Catch is that some object storage solutions are overlayed on top of lower level file systems that do things such as RAID 6, granted they are out of sight, out of mind.

RAID comparison
General RAID parity and erasure code/FEC comparisons

Then there are advanced parity protection schemes which include FEC and erasure codes that while they are not your traditional RAID levels, they have characteristic including chunking or sharding data, spreading it out over multiple devices with multiple parity (or derivatives of parity) protection.

Bottom line is that for some environments, different RAID levels may be more applicable and alive than for others.

Via BizTech – How to Turn Storage Networks into Better Performers

  • Maintain Situational Awareness
  • Design for Performance and Availability
  • Determine Networked Server and Storage Patterns
  • Make Use of Applicable Technologies and Techniques

If RAID is alive, what to do with it?

If you are new to RAID, learn more about the past, present and future keeping mind context. Keeping context in mind means that there are different RAID levels and implementations for various environments. Not all RAID 0, 1, 1/0, 10, 2, 3, 4, 5, 6 or other variations (past, present and emerging) are the same for consumer vs. SOHO vs. SMB vs. SME vs. Enterprise, nor are the usage cases. Some need performance for reads, others for writes, some for high-capacity with low performance using hardware or software. RAID Rules of thumb are ok and useful, however keep them in context to what you are doing as well as using.

What to do next?

Take some time to learn, ask questions including what to use when, where, why and how as well as if an approach or recommendation are applicable to your needs. Check out the following links to read some extra perspectives about RAID and keep in mind, what might apply to enterprise may not be relevant for consumer or SMB and vise versa.

Some advise needed on SSD’s and Raid (Via Spiceworks)
RAID 5 URE Rebuild Means The Sky Is Falling (Via BenchmarkReview)
Double drive failures in a RAID-10 configuration (Via SearchStorage)
Industry Trends and Perspectives: RAID Rebuild Rates (Via StorageIOblog)
RAID, IOPS and IO observations (Via StorageIOBlog)
RAID Relevance Revisited (Via StorageIOBlog)
HDDs Are Still Spinning (Rust Never Sleeps) (Via InfoStor)
When and Where to Use NAND Flash SSD for Virtual Servers (Via TheVirtualizationPractice)
What’s the best way to learn about RAID storage? (Via Spiceworks)
Design considerations for the host local FVP architecture (Via Frank Denneman)
Some basic RAID fundamentals and definitions (Via SearchStorage)
Can RAID extend nand flash SSD life? (Via StorageIOBlog)
I/O Performance Issues and Impacts on Time-Sensitive Applications (Via CMG)
The original RAID white paper (PDF) that while over 20 years old, it provides a basis, foundation and some history by Katz, Gibson, Patterson et al
Storage Interview Series (Via Infortrend)
Different RAID methods (Via RAID Recovery Guide)
A good RAID tutorial (Via TheGeekStuff)
Basics of RAID explained (Via ZDNet)
RAID and IOPs (Via VMware Communities)

Where To Learn More

View additional NAS, NVMe, SSD, NVM, SCM, Data Infrastructure and HDD related topics via the following links.

Additional learning experiences along with common questions (and answers), as well as tips can be found in Software Defined Data Infrastructure Essentials book.

Software Defined Data Infrastructure Essentials Book SDDC

What This All Means

What is my favorite or preferred RAID level?

That depends, for some things its RAID 1, for others RAID 10 yet for others RAID 4, 5, 6 or DP and yet other situations could be a fit for RAID 0 or erasure codes and FEC. Instead of being focused on just one or two RAID levels as the solution for different problems, I prefer to look at the environment (consumer, SOHO, small or large SMB, SME, enterprise), type of usage (primary or secondary or data protection), performance characteristics, reads, writes, type and number of drives among other factors. What might be a fit for one environment would not be a fit for others, thus my preferred RAID level along with where implemented is the one that meets the given situation. However also keep in mind is tying RAID into part of an overall data protection strategy, remember, RAID is not a replacement for backup.

What this all means

Like other technologies that have been declared dead for years or decades, aka the Zombie technologies (e.g. dead yet still alive) RAID continues to be used while the technologies evolves. There are specific products, implementations or even RAID levels that have faded away, or are declining in some environments, yet alive in others. RAID and its variations are still alive, however how it is used or deployed in conjunction with other technologies also is evolving.

Ok, nuff said, for now.

Gs

Greg Schulz – Microsoft MVP Cloud and Data Center Management, VMware vExpert 2010-2017 (vSAN and vCloud). Author of Software Defined Data Infrastructure Essentials (CRC Press), as well as Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press), Resilient Storage Networks (Elsevier) and twitter @storageio. Courteous comments are welcome for consideration. First published on https://storageioblog.com any reproduction in whole, in part, with changes to content, without source attribution under title or without permission is forbidden.

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO. All Rights Reserved. StorageIO is a registered Trade Mark (TM) of Server StorageIO.

Nand flash SSD NVM SCM server storage I/O memory conversations

Updated 8/31/19
Server Storage I/O storageioblog SDDC SDDI Data Infrastructure trends

The SSD Place NVM, SCM, PMEM, Flash, Optane, 3D XPoint, MRAM, NVMe Server, Storage, I/O Topics

Now and then somebody asks me if I’m familiar with flash or nand flash Solid State Devices (SSD) along with other non-volatile memory (NVM) technologies and trends including NVM Express (NVMe).

Having been involved with various types of SSD technology, products and solutions since the late 80s initially as a customer in IT (including as a lunch customer for DEC’s ESE20 SSD’s), then later as a vendor selling SSD solutions, as well as an analyst and advisory consultant cover the technologies, I tell the person asking, well, yes, of course.

That gave me the idea as well as to help me keep track of some of the content and make it easy to find by putting it here in this post (which will be updated now and then).

Thus this is a collection of articles, tips, posts, presentations, blog posts and other content on SSD including nand flash drives, PCIe cards, DIMMs, NVM Express (NVMe), hybrid and other storage solutions along with related themes.

Also if you can’t find it here, you can always do a Google search like this or this to find some more material (some of which is on this page).

HDD, SSHD, HHDD and HDD

Flash SSD Articles, posts and presentations

The following are some of my tips, articles, blog posts, presentations and other content on SSD. Keep in mind that the question should not be if SSD are in your future, rather when, where, with what, from whom and how much. Also keep in mind that a bit of SSD as storage or cache in the right place can go a long way, while a lot of SSD will give you a benefit however also cost a lot of cash.

  • How to Prepare for the NVMe Server Storage I/O Wave (Via Micron.com)
  • Why NVMe Should Be in Your Data Center (Via Micron.com)
  • NVMe U2 (8639) vs. M2 interfaces (Via Gamersnexus)
  • Enmotus FuzeDrive MicroTiering (StorageIO Lab Report)
  • EMC DSSD D5 Rack Scale Direct Attached Shared SSD All Flash Array Part I (Via StorageIOBlog)
  • Part II – EMC DSSD D5 Direct Attached Shared AFA (Via StorageIOBlog)
  • NAND, DRAM, SAS/SCSI & SATA/AHCI: Not Dead, Yet! (Via EnterpriseStorageForum)
  • Non Volatile Memory (NVM), NVMe, Flash Memory Summit and SSD updates (Via StorageIOblog)
  • Microsoft and Intel showcase Storage Spaces Direct with NVM Express at IDF ’15 (Via TechNet)
  • MNVM Express solutions (Via SuperMicro)
  • Gaining Server Storage I/O Insight into Microsoft Windows Server 2016 (Via StorageIOblog)
  • PMC-Sierra Scales Storage with PCIe, NVMe (Via EEtimes)
  • RoCE updates among other items (Via InfiniBand Trade Association (IBTA) December Newsletter)
  • NVMe: The Golden Ticket for Faster Flash Storage? (Via EnterpriseStorageForum)
  • What should I consider when using SSD cloud? (Via SearchCloudStorage)
  • MSP CMG, Sept. 2014 Presentation (Flash back to reality – Myths and Realities – Flash and SSD Industry trends perspectives plus benchmarking tips)– PDF
  • Selecting Storage: Start With Requirements (Via NetworkComputing)
  • PMC Announces Flashtec NVMe SSD NVMe2106, NVMe2032 Controllers With LDPC (Via TomsITpro)
  • Exclusive: If Intel and Micron’s “Xpoint” is 3D Phase Change Memory, Boy Did They Patent It (Via Dailytech)
  • Intel & Micron 3D XPoint memory — is it just CBRAM hyped up? Curation of various posts (Via Computerworld)
  • How many IOPS can a HDD, HHDD or SSD do (Part I)?
  • How many IOPS can a HDD, HHDD or SSD do with VMware? (Part II)
  • I/O Performance Issues and Impacts on Time-Sensitive Applications (Via CMG)
  • Via EnterpriseStorageForum: 5 Hot Storage Technologies to Watch
  • Via EnterpriseStorageForum: 10-Year Review of Data Storage
  • Via CustomPCreview: Samsung SM961 PCIe NVMe SSD Shows Up for Pre-Order
  • StorageIO Industry Trends Perspective White Paper: Seagate 1200 Enterprise SSD (12Gbps SAS) with proof points (e.g. Lab test results)
  • Companion: Seagate 1200 12Gbs Enterprise SAS SSD StorgeIO lab review (blog post part I and Part II)
  • NewEggBusiness: Seagate 1200 12Gbs Enterprise SAS SSD StorgeIO lab review Are NVMe m.2 drives ready for the limelight?
  • Google (Research White Paper): Disks for Data Centers (vs. just SSD)
  • CMU (PDF White Paper): A Large-Scale Study of Flash Memory Failures in the Field
  • Via ZDnet: Google doubles Cloud Compute local SSD capacity: Now it’s 3TB per VM
  • EMC DSSD D5 Rack Scale Direct Attached Shared SSD All Flash Array Part I (Via StorageIOBlog)
  • Part II – EMC DSSD D5 Direct Attached Shared AFA (Via StorageIOBlog)
  • NAND, DRAM, SAS/SCSI & SATA/AHCI: Not Dead, Yet! (Via EnterpriseStorageForum)
  • Here’s why Western Digital is buying SanDisk (Via ComputerWorld)
  • HP, SanDisk partner to bring storage-class memory to market (Via ComputerWorld)
  • Non Volatile Memory (NVM), NVMe, Flash Memory Summit and SSD updates (Via StorageIOblog)
  • Microsoft and Intel showcase Storage Spaces Direct with NVM Express at IDF ’15 (Via TechNet)
  • PMC-Sierra Scales Storage with PCIe, NVMe (Via EEtimes)
  • Seagate Grows Its Nytro Enterprise Flash Storage Line (Via InfoStor)
  • New SAS Solid State Drive First Product From Seagate Micron Alliance (Via Seagate)
  • Wow, Samsung’s New 16 Terabyte SSD Is the World’s Largest Hard Drive (Via Gizmodo)
  • Samsung ups the SSD ante with faster, higher capacity drives (Via ITworld)
  • PMC Announces Flashtec NVMe SSD NVMe2106, NVMe2032 Controllers With LDPC (Via TomsITpro)
  • New SATA SSD powers elastic cloud agility for CSPs (Via Cbronline)
  • Toshiba Solid-State Drive Family Features PCIe Technology (Via Eweek)
  • SanDisk aims CloudSpeed Ultra SSD at cloud providers (Via ITwire)
  • Everspin & Aupera reveal all-MRAM Storage Module in M.2 Form Factor (Via BusinessWire)
  • Intel, Micron Launch “Bulk-Switching” ReRAM (Via EEtimes)
  • Exclusive: If Intel and Micron’s “Xpoint” is 3D Phase Change Memory, Boy Did They Patent It (Via Dailytech)
  • Intel & Micron 3D XPoint memory — is it just CBRAM hyped up? Curation of various posts (Via Computerworld)
  • NVMe: The Golden Ticket for Faster Flash Storage? (Via EnterpriseStorageForum)

server I/O hirearchy

  • What should I consider when using SSD cloud? (Via SearchCloudStorage)
  • MSP CMG, September 2014 Presentation (Flash back to reality – Myths and Realities Flash and SSD Industry trends perspectives plus benchmarking tips) – PDF
  • Selecting Storage: Start With Requirements (Via NetworkComputing)
  • Spot The Newest & Best Server Trends (Via Processor)
  • Market ripe for embedded flash storage as prices drop (Via Powermore (Dell))
  • 2015 Tech Preview: SSD and SMBs (Via ChannelProNetworks )
  • How to test your HDD, SSD or all flash array (AFA) storage fundamentals (Via StorageIOBlog)
  • Processor: Comments on What Abandoned Data Is Costing Your Company
  • Processor: Comments on Match Application Needs & Infrastructure Capabilities
  • Processor: Comments on Explore The Argument For Flash-Based Storage
  • Processor: Comments on Understand The True Cost Of Acquiring More Storage
  • Processor: Comments on What Resilient & Highly Available Mean
  • Processor: Explore The Argument For Flash-Based Storage
  • SearchCloudStorage What should I consider when using SSD cloud?
  • StorageSearch.com: (not to be confused with TechTarget, good site with lots of SSD related content)
  • StorageSearch.com: What kind of SSD world… 2015?
  • StorageSearch.com: Various links about SSD
  • FlashStorage.com: (Various flash links curated by Tegile and analyst firm Actual Tech Media [Scott D. Lowe])
  • StorageSearch.com: How fast can your SSD run backwards?
  • Seagate has shipped over 10 Million storage HHDD’s (SSHDs), is that a lot?
  • Are large storage arrays dead at the hands of SSD?
  • Can we get a side of context with them IOPS and other storage metrics?
  • Cisco buys Whiptail continuing the SSD storage I/O flash cash cache dash
  • EMC VFCache respinning SSD and intelligent caching (Part I)
  • Flash Data Storage: Myth vs. Reality (Via InfoStor)
  • Have SSDs been unsuccessful with storage arrays (with poll)?
  • How many IOPS can a HDD, HHDD or SSD do (Part I)?
  • How many IOPS can a HDD, HHDD or SSD do with VMware? (Part II)
  • I/O Performance Issues and Impacts on Time-Sensitive Applications (Via CMG)

server storage i/o memory hirearchy

  • Spiceworks SSD and related conversation here and here, profiling IOPs here, and SSD endurance here.
  • SSD is in your future, How, when, with what and where you will be using it (PDF Presentation)
  • SSD for Virtual (and Physical) Environments: Part I Spinning up to speed on SSD (Via TheVirtualizationPractice), Part II, The call to duty, SSD endurance, Part III What SSD is best for you?, and Part IV what’s best for your needs.
  • IT and storage economics 101, supply and demand
  • SSD, flash and DRAM, DejaVu or something new?
  • The Many Faces of Solid State Devices/Disks (SSD)
  • The Nand Flash Cache SSD Cash Dance (Via InfoStor)
  • The Right Storage Option Is Important for Big Data Success (Via FedTech)

server storage i/o nand flash ssd options

  • Viking SATADIMM: Nand flash SATA SSD in DDR3 DIMM slot?
  • WD buys nand flash SSD storage I/O cache vendor Virident (Via VMware Communities)
  • What is the best kind of IO? The one you do not have to do
  • When and Where to Use NAND Flash SSD for Virtual Servers (Via TheVirtualizationPractice)
  • Why SSD based arrays and storage appliances can be a good idea (Part I)
  • Why SSD based arrays and storage appliances can be a good idea (Part II)
  • Q&A on Access data more efficiently with automated storage tiering and flash (Via SearchSolidStateStorage)
  • InfoStor: Flash Data Storage: Myth vs. Reality (Via InfoStor)
  • Enterprise Storage Forum: Not Just a Flash in the Pan (Via EnterpriseStorageForum)

SSD Storage I/O and related technologies comments in the news

The following are some of my commentary and industry trend perspectives that appear in various global venues.

Storage I/O ssd news

  • Comments on using Flash Drives To Boost Performance (Via Processor)
  • Comments on selecting the Right Type, Amount & Location of Flash Storage (Via Toms It Pro)
  • Comments Google vs. AWS SSD: Which is the better deal? (Via SearchAWS)
  • Tech News World: SANdisk SSD comments and perspectives.
  • Tech News World: Samsung Jumbo SSD drives perspectives
  • Comments on Why Degaussing Isn’t Always Effective (Via StateTech Magazine)
  • Processor: SSD (FLASH and RAM)
  • SearchStorage: FLASH and SSD Storage
  • Internet News: Steve Wozniak joining SSD startup
  • Internet News: SANdisk sale to Toshiba
  • SearchSMBStorage: Comments on SanDisk and wireless storage product
  • StorageAcceleration: Comments on When VDI Hits a Storage Roadblock and SSD
  • Statetechmagazine: Boosting performance with SSD
  • Edtechmagazine: Driving toward SSDsStorage I/O trends
  • SearchStorage: Seagate SLC and MLC flash SSD
  • SearchWindowServer: Making the move to SSD in a SAN/NAS
  • SearchSolidStateStorage: Comments SSD marketplace
  • InfoStor: Comments on SSD approaches and opportunities
  • SearchSMBStorage: Solid State Devices (SSD) benefits
  • SearchSolidState: Comments on Fusion-IO flash SSD and API’s
  • SeaarchSolidStateStorage: Comments on SSD industry activity and OCZ bankruptcy
  • Processor: Comments on Plan Your Storage Future including SSD
  • Processor: Comments on Incorporate SSDs Into Your Storage PlanStorage I/O ssd news
  • Digistor: Comments on SSD and flash storage
  • ITbusinessEdge: Comments on flash SSD and hybrid storage environments
  • SearchStorage: Perspectives on Cisco buying SSD storage vendor Whiptail
  • StateTechMagazine: Comments on all flash SSD storage arrays
  • Processor: Comments on choosing SSDs for your data center needs
  • Searchsolidstatestorage: Comments on how to add solid state devices (SSD) to your storage system
  • Networkcomputing: Comments on SSD/Hard Disk Hybrids Bridge Storage Divide
  • Internet Evolution: Comments on IBM buying flash SSD vendor TMS
  • ITKE: Comments on IBM buying flash SSD vendor TMSStorage I/O trends
  • Searchsolidstatestorage: SSD, Green IT and economic benefits
  • IT World Canada: Cloud computing, dot be scared, look before you leap
  • SearchStorage: SSD in storage systems
  • SearchStorage: SAS SSD
  • SearchSolidStateStorage: Comments on Access data more efficiently with automated storage tiering and flash
  • InfoStor: Comments on EMC’s Light to Speed: Flash, VNX, and Software-Defined
  • EnterpriseStorageForum: Cloud Storage Mergers and Acquisitions: What’s Going On?

Check out the Server StorageIO NVM Express (NVMe) focus page aka www.thenvmeplace.com for additional related content. nterested in data protection, check out the data protection diaries series of posts here, or cloud and object storage here, and server storage I/O performance benchmarking here. Also check out the StorageIO events and activities page here, as well as tips and articles here, news commentary here, along out newsletter here.

Ok, nuff said (for now)

Cheers
Gs

Greg Schulz – Author Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press) and Resilient Storage Networks (Elsevier)
twitter @storageio

All Comments, (C) and (TM) belong to their owners/posters, Other content (C) Copyright 2006-2024 Server StorageIO and UnlimitedIO LLC All Rights Reserved

How much storage performance do you want vs. need?

Storage I/O trends

How much storage I/O performance do you want vs. need?

The answer to how much storage I/O performance you need vs. want probably depends on cost, for which applications along with benefit among other things.

Storage I/O performance
View Part II: How many IOPS can a HDD, HHDD or SSD do with VMware?

I did a piece over at 21cit titled Parsing the Need for Speed in Storage that looks at those and other related themes including metrics that matter across tiered storage.

Here is an excerpt:

Can storage speed be too fast? Or, put another away, how do you decide a return on investments or innovation from the financial resources you spend on storage and the various technologies that go into storage performance.

Think about it: Fast storage needs fast servers, IO and networking interfaces, software, firmware, hypervisors, operating systems, drivers, and a file system or database, along with applications. Then there are the other buzzword bingo technologies that are also factors, among them fast storage DRAM and flash Solid State Devices (SSD).

Some questions to ask about storage I/O performance include among others:

  • How do response time, latency, and think or wait-times effect your environment and applications?
  • Do you know the location of your storage or data center performance bottlenecks?
  • If you remove bottlenecks in storage systems or appliances as well as in the data path, how will your application or the CPU in the server it runs on behave?
  • If your application server is currently showing high CPU due to the system overhead of having to wait for storage I/Os, you may see a positive improvement.
  • If more real work can be done now, will all of the components be ready to support each other without creating a new bottleneck?
  • Also speaking of storage I/O performance, how about can we get a side of context with them IOPs and other metrics that matter!

So how about it, how much performance, for primary, secondary, backup, cloud or virtual storage do you want vs. need?

Ok, nuff said for now.

Cheers
Gs

Greg Schulz – Author Cloud and Virtual Data Storage Networking (CRC Press), The Green and Virtual Data Center (CRC Press) and Resilient Storage Networks (Elsevier)
twitter @storageio